DC Power Source for Hydrogen Electrolyzer

Product Range:

● Module: standard 1MW

● Multiple modules in parallel to configure 10MW

● Multiple cabinets in parallel to configure 20MW~200MW

    description1

    description2

    Chindow, as a R&D oriented company in the world that manufactures both(Active Front End)rectifier based and Diode based power supply of hydrogen electrolyzer

    Specifications

    Power Supply of Hydrogen Electrolyzer with AFE rectifier+IGBT

    Power Capacity: 1 MW per module; scalable up to 10 MW with 10 modules connected in parallel 

    Grid Input: Three-phase, three-wire 11 kV AC, 50 Hz

    DC Output Voltage: 0–648 VDC, continuously adjustable

    Output Current: 1,543 A at 648 V or up to 3,334 A at 300 V per module

    Power Conversion Efficiency: ≥98.5%

    Power Factor: ≥0.99 

    THDi: ≤3% 

    Voltage and Current Regulation Accuracy: ≤±0.5% 

    Output Current Ripple: ≤1% 

    Cooling: Customizable air or water cooling

    Protection Level: IP20 for modules and IP30 for the complete indoor system 

    Communication: RS485/Ethernet communication with Modbus support

    Control: Automatic switching between constant-voltage and constant-current modes

    Specification (1)(1)

    Power Supply of Hydrogen Electrolyzer with Diode +IGBT

    Power Capacity: 1 MW per module; scalable up to 10 MW with 10 modules connected in parallel

    Grid Input: Three-phase, three-wire 11 kV AC, 50 Hz

    DC Output: 0–648 VDC, continuously adjustable

    Power Conversion Efficiency: ≥97.5%

    Power Factor: ≥0.94

    THDi: ≤27%

    Control Accuracy: Voltage and current regulation accuracy ≤±0.5%

    Cooling Method: Air cooling or water cooling

    Protection Level: IP20 for individual modules and IP30 for the complete indoor system

    Communication and Control: RS485/Ethernet communication with Modbus support

    Control: Automatic switching between constant-voltage and constant-current modes

    Specification (2)(1)

    Key Features

    Chindow AFE rectifier based power supply increasing the efficiency by 5~9% compared with mid frequency power supply with SCR serving as rectifier and inverter circuit

    Chindow AFE (1)(1)
    Chindow AFE (2)(1)

    For Chindow AFE rectifier based power supply, a conventional transformer can be used instead of a complex phase-shifting transformer is compulsory for SCR based power supply, which will significantly reduce costs for the entire system

    Conventional transformer for AFE rectifier based power supply

    Conventional transformer for AFE rectifier based power supply

    Phase shifting transformer for SCR based power supply

    Phase shifting transformer for SCR based power supply

    Chindow AFE rectifier based power supply reduced one third footprint compared with the SCR based power supply