Leave Your Message

Power Supply For Electrostatic Precipitator

● G5 HFPS of ESP (5th Generation High Frequency Power Supply of Electrostatic Precipitator)

● G4 HFPS of ESP (4th Generation High Frequency Power Supply of Electrostatic Precipitator)

● Mid-frequency power supply for ESP

We provide key components (SKD, CKD, Tech transfer) of G4/G5 HFPS

Supporting worldwide partners in local manufacturing of above products

    description1

    description2

    G5 HFPS of ESP
    (60kV ~ 120kV, 200mA ~ 3000mA)

    G4 HFPS of ESP
    (60kV ~ 120kV, 200mA ~2000mA)

    Mid-frequency power supply for ESP
    (60kV ~ 120kV, 200mA ~ 2000mA)

    Specifications

    G5 HFPS of ESP

    AC Input Voltage: Three-phase 380–480 VAC ±15%, 50/60 Hz ±10%

    Current Control Accuracy: ±0.5%

    Power Conversion Efficiency: ≥94%

    Power Factor: ≥0.99

    Operating Frequency: ≥30kHz

    Operating Functions: Back-Corona Control and Pulse Mode Operation

    Cooling Method: Forced-air cooling

    Protection Level: IP54

    Communication Interface: RS485/Internet

    Control and Display: HMI-based digital control and monitoring

    G4 HFPS of ESP

    AC Input Voltage: Three-phase 380-480 VAC ±15%, 50/60 Hz ±10%

    Current Control Accuracy: ±0.5%

    Power Conversion Efficiency: ≥92%

    Power Factor: ≥0.92

    Operating Frequency: ≥30 kHz, up to 40 kHz

    Operating Modes: Spark Rate Control, Energy-Saving Mode and Pulse Mode

    Cooling Method: Forced-air cooling

    Transformer Type: Oil-immersed transformer

    Communication: RS485/Internet communication with HMI monitoring

    Protection Level: IP54

    Mid-frequency power supply of ESP

    AC Input: Single-phase/three-phase 415 VAC ±15%

    Output Frequency: 400 Hz

    Power Conversion Efficiency: ≥88%

    Power Factor: ≥0.90

    Operating Modes: Spark Rate Control, Energy-Saving Mode and Pulse Mode

    Cooling Method: Forced-air cooling

    Protection Level: IP20

    Communication Interface: RS485/Internet

    Control and Display: HMI-based control and monitoring

    Chindow is the only technology origin in the world that design and manufacture G5 HFPS of ESP

    Key Features
    Chindow G5 HFPS (1)(1)
    Chindow G5 HFPS (2)(1)
    Chindow G5 HFPS (3)(1)
    Chindow G5 HFPS (4)

    Chindow G5 HFPS dust collection performance is enhanced by 25%~40% compared with G2 single phase 50Hz TR & CC

    Transformer (1)(1)
    Transformer (2)(1)

    Transformer oil maintenance cycle of G5 HFPS is reduced to 15years while G2 transformer oil has to be filter every 2/3 years

    For G2 single phase 50Hz TR & CC, the sparking current uncontrolled, similar to short circuit
    For G5 HFPS of ESP, the sparking current is well controlled and limited to rated current.
    G5 HFPS is equipped with both

    G5 HFPS is equipped with both back corona and pulse mode function to tackle respectively back corona and high resistivity

    The G5 generates low harmonics 5% and therefore requires no additional harmonic filter compare to G2 with 35% THDi

    Waveform Comparison

    Chindow G5 HFPS
    VS
    G4 HFPS
    VS
    G2 single phase 50Hz TR & CC

    It is common sense that ideal waveform of voltage and current is a stable one.

    Waveform Comparison (1)(1)
    Waveform Comparison (2)

    Industries Applicable

    Power plant

    Paper mill

    Pulp plant

    Textile

    Mining

    Petrochemical plant

    Sugar plants

    Steel works

    Pharmaceutical plant

    Click for inquiry